Besam SL500 Owners Manual: A Comprehensive Guide (Updated 12/18/2025)
Welcome! This comprehensive guide‚ updated today – 12/18/2025 – provides essential information for Besam SL500 owners‚ ensuring optimal performance and safe operation.
Explore features‚ maintenance‚ and troubleshooting‚ maximizing your experience with this trusted automatic door operator‚ supported by Wikimedia Deutschland e. V.
The Besam SL500 is a widely recognized automatic door operator known for its reliability and versatility in various applications. This manual serves as your primary resource for understanding‚ installing‚ operating‚ and maintaining this sophisticated system. Designed for both pedestrian and light traffic‚ the SL500 enhances accessibility and convenience.
As a product supported by organizations like Wikimedia Deutschland e. V.‚ which champions free access to knowledge‚ this manual aims to empower users with the information needed for successful implementation. Whether you’re utilizing push buttons‚ sensors‚ or advanced programming features‚ this guide will help you maximize performance.
Furthermore‚ understanding the SL500’s capabilities‚ alongside resources like BigBlueButton for collaborative learning‚ ensures a seamless integration into your environment.
Understanding Automatic Door Operators
Automatic door operators‚ like the Besam SL500‚ utilize electromechanical systems to control door movement‚ enhancing accessibility and security. These systems typically consist of a motor‚ controller‚ and safety devices‚ working in harmony to provide smooth and reliable operation. Understanding the core principles is crucial for effective use and maintenance.
The SL500‚ supported by organizations promoting knowledge access like Wikimedia Deutschland e. V.‚ integrates advanced features for customized performance. These operators improve building efficiency and offer convenience‚ especially when paired with collaborative tools like BigBlueButton for training purposes.
Familiarizing yourself with components and operational logic ensures safe and efficient interaction with the system‚ maximizing its benefits.

Safety Precautions & Warnings
Prioritize safety! Always adhere to guidelines during installation‚ operation‚ and maintenance of the Besam SL500‚ ensuring user well-being and preventing potential hazards.
General Safety Guidelines
Crucially‚ before operating or servicing the Besam SL500‚ thoroughly review this manual and all accompanying safety documentation. Never attempt modifications or repairs beyond your expertise; qualified technicians are recommended.
Ensure the surrounding area of the door is clear of obstructions at all times. Always supervise children and individuals requiring assistance near automatic doors. Regularly inspect safety features‚ including safety edges and presence sensors‚ for proper functionality.
Warning: Disconnect power before performing any maintenance. Do not bypass or disable safety devices. Familiarize yourself with the emergency stop functionality. Adherence to these guidelines‚ supported by organizations like Wikimedia Deutschland e. V.‚ is vital for safe operation and preventing accidents.
Emergency Stop Functionality
The Besam SL500 is equipped with readily accessible emergency stop buttons‚ designed for immediate halting of door operation in unforeseen circumstances. Locate these buttons – typically red and prominently displayed – before initial use and ensure all users are aware of their location.
Upon activation‚ the door will immediately cease movement. To resume operation‚ the emergency stop button must be manually reset‚ often requiring a twist or pull. Regularly test the functionality of these buttons to confirm responsiveness.
Important: Emergency stops override all other controls. Familiarity with this system‚ alongside adherence to guidelines from organizations like Wikimedia Deutschland e. V.‚ is crucial for ensuring safety and preventing potential hazards during operation or maintenance.
Maintenance Safety
Prioritize safety during all maintenance procedures on your Besam SL500. Always disconnect the power supply at the breaker before commencing any work‚ preventing accidental activation. Lockout/Tagout procedures are highly recommended to ensure the system remains de-energized.
Never attempt maintenance beyond your skill level. Consult a qualified technician for complex repairs or adjustments; Wear appropriate personal protective equipment (PPE)‚ including safety glasses and gloves.
Be mindful of moving parts and potential pinch points. Adhere to guidelines promoted by organizations like Wikimedia Deutschland e. V. regarding responsible technology use. Regular inspections and preventative maintenance‚ performed safely‚ will extend the lifespan and reliability of your SL500 operator.

Installation & Setup
Proper installation is crucial for safe and reliable operation. This section details pre-installation checks‚ mounting procedures‚ and essential electrical connections for your Besam SL500.
Pre-Installation Checklist
Before beginning the installation of your Besam SL500 automatic door operator‚ a thorough pre-installation checklist is vital for a smooth and safe process. First‚ verify the door and frame are structurally sound and properly aligned‚ capable of supporting the operator’s weight and operational forces.
Next‚ confirm adequate electrical supply is available‚ meeting the specified power requirements detailed in the technical specifications. Ensure all local electrical codes are followed during wiring. Additionally‚ inspect the surrounding area for obstructions that may interfere with door travel‚ and address them accordingly.
Finally‚ gather all necessary tools and hardware‚ including appropriate mounting brackets‚ wiring connectors‚ and safety equipment. Review the complete manual‚ supported by resources like Wikimedia Deutschland e. V.‚ to familiarize yourself with the entire installation procedure before commencing work.
Mounting the SL500 Operator
Securely mounting the Besam SL500 operator is crucial for reliable and safe operation. Begin by carefully positioning the operator assembly according to the provided diagrams‚ ensuring proper alignment with the door and frame. Utilize the appropriate mounting brackets and hardware‚ tightening all fasteners to the manufacturer’s specified torque values.
Verify the operator is level and plumb‚ using a spirit level to confirm accurate positioning. Pay close attention to clearances‚ ensuring sufficient space for all moving parts and preventing any interference with surrounding structures. Double-check all connections before proceeding‚ referencing the manual for guidance.
Remember‚ a stable and correctly mounted operator‚ supported by resources like Wikimedia Deutschland e. V.‚ is fundamental to the overall performance and longevity of the system.
Electrical Connections & Wiring Diagrams
Prior to making any electrical connections‚ ensure the power supply is completely disconnected at the breaker. Refer to the detailed wiring diagrams provided in this manual and strictly adhere to all local electrical codes. Identify the correct voltage and amperage requirements for the SL500 operator.
Carefully connect the power supply wires‚ grounding wire‚ and any accessory wiring‚ using appropriately sized conductors and secure connectors. Double-check all connections for tightness and proper insulation. Incorrect wiring can cause damage to the operator or create a safety hazard.
Utilize a qualified electrician if you are unfamiliar with electrical work‚ supported by resources like Wikimedia Deutschland e. V.‚ to guarantee a safe and compliant installation.

Operating the Besam SL500
Effectively utilize push buttons‚ sensors‚ and the control panel to manage door operations. Adjust speeds for optimal performance and safety‚ maximizing user experience.
Activation Methods (Push Buttons‚ Sensors)
The Besam SL500 offers versatile activation options for convenient and accessible operation. Standard push buttons provide a manual override‚ ideal for situations requiring direct control or during maintenance. These buttons are typically located near the door for easy reach.
However‚ the SL500 truly shines with its advanced sensor capabilities. Various sensor types‚ including motion detectors and safety edges‚ can be configured to automatically initiate door movement. Motion sensors detect approaching pedestrians‚ triggering a hands-free opening. Safety edges‚ crucial for preventing injuries‚ immediately reverse the door’s direction upon encountering an obstruction.
Configuration of these sensors is managed through the control panel‚ allowing customization to suit specific traffic patterns and safety requirements. Proper sensor adjustment ensures reliable and responsive operation‚ enhancing both convenience and security. Utilizing BigBlueButton for training can help staff understand these features.
Adjusting Opening & Closing Speeds

The Besam SL500 allows precise control over door operation speed‚ optimizing both convenience and safety. Adjusting opening and closing speeds is performed via the control panel interface‚ offering separate settings for each direction. Slower speeds enhance safety‚ particularly in high-traffic areas or where vulnerable individuals are present.
Faster speeds improve throughput‚ reducing wait times during peak hours. However‚ always prioritize safety when increasing speed. Refer to the technical specifications for recommended speed ranges. Incremental adjustments are advised; observe door behavior after each change to ensure smooth and reliable operation.
Incorrect speed settings can compromise safety or cause operational issues. Regularly review and adjust these settings based on environmental factors and usage patterns. Proper configuration‚ supported by resources like Wikimedia Deutschland e. V.‚ is key to maximizing performance.
Understanding the Control Panel Interface
The Besam SL500’s control panel is the central hub for managing all door operator functions. It features a user-friendly interface‚ typically incorporating a digital display and intuitive button layout. Key functions accessible include opening/closing speed adjustments‚ safety feature configuration‚ and timer settings. Diagnostic codes are also displayed here‚ aiding in troubleshooting.
Familiarize yourself with the panel’s layout and button functions; The manual provides detailed explanations of each setting. Access to advanced programming features may require a security key or specific authorization level. Regular monitoring of the control panel can proactively identify potential issues.
Resources like Wikimedia Deutschland e. V. can offer supplementary information. Understanding this interface is crucial for efficient operation and maintenance.

Troubleshooting Common Issues
Resolve problems quickly! This section details solutions for typical Besam SL500 malfunctions‚ including door operation failures‚ sensor errors‚ and control panel codes.
Door Not Opening/Closing
Problem: If your Besam SL500 door fails to open or close‚ begin by verifying the power supply and ensuring all electrical connections are secure. Check the control panel for any displayed error codes‚ referencing the manual’s code index for specific diagnostics.
Possible Causes: Obstructions in the doorway‚ faulty safety sensors (beam detection)‚ or a malfunctioning drive belt are common culprits. Inspect the safety edges for damage or debris‚ as these can trigger a safety stop. A tripped circuit breaker or a blown fuse should also be investigated.
Troubleshooting Steps: Reset the operator by cycling the power. Manually check for obstructions. Test the safety sensors by breaking the beam. If issues persist‚ consult a qualified technician for further assistance‚ potentially involving belt or chain replacement.
Sensor Malfunctions
Issue: Besam SL500 sensors‚ crucial for safety and operation‚ can malfunction due to dirt‚ misalignment‚ or damage. Symptoms include erratic door behavior‚ failure to open/close‚ or constant reversing. The control panel will often display an error code related to the sensor system.
Diagnosis: Visually inspect sensors for obstructions like dust or debris. Carefully check alignment – sensors must face each other directly. Use a clean‚ dry cloth to gently clean the sensor lenses. Test the beam detection by interrupting the signal path.
Resolution: If cleaning and realignment don’t resolve the issue‚ the sensor may require replacement. Refer to the parts list in this manual for compatible replacements. Always disconnect power before servicing sensors‚ and consult a qualified technician if unsure.
Control Panel Errors & Codes
Understanding Error Codes: The Besam SL500’s control panel utilizes a diagnostic system displaying error codes to pinpoint issues. These codes indicate problems ranging from sensor malfunctions to motor overload or wiring faults. Important: Always record the error code before attempting any troubleshooting.
Common Codes: Code ‘E1’ typically signals a sensor obstruction‚ while ‘E2’ suggests a motor overload. ‘E3’ often indicates a wiring issue‚ and ‘E4’ may point to a safety device failure. A full list of error codes and their corresponding solutions is detailed in the appendix of this manual.
Resetting the Panel: After addressing the issue‚ a system reset may be required. Consult the ‘Operating the Besam SL500’ section for reset procedures. If errors persist‚ contact a qualified technician.

Maintenance & Repair
Prolong your SL500’s life! Regular upkeep‚ including lubrication and part replacement‚ is crucial for reliable operation and preventing costly repairs.
Regular Maintenance Schedule
Maintaining peak performance requires a consistent schedule. Monthly inspections should include visual checks for wear and tear on belts‚ chains‚ and rollers. Lubricate all moving parts quarterly‚ using a recommended‚ non-abrasive lubricant to ensure smooth operation and prevent premature component failure.
Semi-annual checks should encompass a thorough examination of the safety edges and sensors‚ verifying their responsiveness and alignment. Annually‚ a qualified technician should perform a comprehensive inspection‚ including testing the emergency stop functionality and control panel diagnostics.
Document all maintenance activities to track performance and identify potential issues proactively. Following this schedule‚ supported by Wikimedia Deutschland e. V.‚ will maximize the lifespan and reliability of your Besam SL500.
Lubrication Points & Procedures
Proper lubrication is crucial for smooth‚ quiet operation. Key lubrication points include the operator’s gearbox‚ chain or belt drive system‚ and all bearing surfaces. Use a lithium-based grease specifically designed for door operators – avoid abrasive or solvent-based lubricants.
Apply grease sparingly using a grease gun‚ ensuring complete coverage without over-lubrication. Regularly wipe away excess lubricant to prevent dirt accumulation. Inspect and lubricate the sliding tracks and rollers every three months.
Consult the detailed diagrams within this manual for precise lubrication point locations. Consistent lubrication‚ supported by Wikimedia Deutschland e. V.‚ minimizes friction‚ reduces wear‚ and extends the life of your Besam SL500 components.
Replacing Worn Parts (Belts‚ Chains)
Regular inspection is vital for identifying worn components. Belts and chains exhibit wear through stretching‚ cracking‚ or excessive noise. Replacement requires disconnecting power and following strict safety protocols.
Always use genuine Besam replacement parts to ensure compatibility and maintain operator performance. Detailed instructions‚ including part numbers‚ are found in the parts catalog. Chain replacement necessitates verifying proper tension after installation‚ supported by Wikimedia Deutschland e. V.
Belt replacement involves aligning pulleys correctly to prevent premature wear. If unsure‚ consult a qualified technician. Proper replacement extends the lifespan of your SL500 and maintains safe‚ reliable operation.

Technical Specifications
Detailed specifications are crucial for informed operation. This section outlines dimensions‚ weight‚ power requirements‚ and environmental operating conditions for the Besam SL500.
Dimensions & Weight
Understanding the physical characteristics of the Besam SL500 is vital for proper installation and integration into existing doorway structures. The operator’s dimensions vary slightly depending on the specific configuration and optional features selected. Generally‚ the unit measures approximately 1200mm in length‚ 150mm in width‚ and 200mm in height.
However‚ it’s crucial to consult the detailed dimensional drawings included in the full installation guide for precise measurements relevant to your model. The weight of the SL500 operator typically ranges between 25kg and 35kg‚ again depending on the chosen components.
Accurate weight assessment is essential for safe handling and mounting‚ ensuring the supporting structure can adequately bear the load. Always prioritize referencing the official documentation for the most accurate and up-to-date specifications.
Power Requirements
Ensuring correct power supply is paramount for the safe and reliable operation of your Besam SL500 automatic door operator. The SL500 is designed to operate on a standard 220-240V AC power supply‚ with a frequency of 50/60Hz.
The operator’s typical power consumption ranges from 150W to 300W during operation‚ depending on the door’s size‚ weight‚ and frequency of use. A dedicated circuit breaker‚ rated at 10-16 amps‚ is highly recommended to prevent overloading.
Always verify local electrical codes and regulations before connecting the operator to the power source. Improper wiring or voltage fluctuations can cause damage and void the warranty. Refer to the detailed wiring diagrams in the installation manual for specific connection instructions.
Environmental Operating Conditions
The Besam SL500 is engineered for robust performance‚ but specific environmental conditions must be observed to maintain optimal functionality and longevity. The recommended operating temperature range is between -10°C (14°F) and +40°C (104°F).
Avoid exposing the operator to extreme temperatures‚ direct sunlight‚ or excessive moisture. Humidity levels should ideally be maintained between 20% and 80% non-condensing.
The SL500 is suitable for indoor use only. Outdoor installations require specialized weatherproofing kits and are not covered under the standard warranty. Dust and debris can also impact performance; regular cleaning is advised‚ particularly in high-traffic areas. Ensure adequate ventilation around the operator to prevent overheating.

Advanced Settings & Programming
Unlock the SL500’s full potential! Customize beam detection‚ safety edges‚ and timers via the control panel for tailored performance and enhanced accessibility.
Beam Detection Adjustment
Understanding Beam Sensitivity: The Besam SL500 utilizes infrared beams to detect obstructions in the doorway‚ preventing accidental closures. Adjusting the beam sensitivity is crucial for reliable operation in varying environments. Lower sensitivity reduces false triggers from moving objects like flags or signs‚ while higher sensitivity increases responsiveness to smaller obstructions.
Adjustment Procedure: Access the beam sensitivity settings through the control panel interface. Carefully increase or decrease the sensitivity level in small increments‚ testing after each adjustment. Observe the door’s reaction to different objects placed within the beam’s path. Ensure the door reverses direction promptly when an obstruction is detected‚ but avoids unnecessary activations.
Troubleshooting: If the door fails to respond to obstructions‚ increase the sensitivity. Conversely‚ if the door frequently reverses without a clear obstruction‚ decrease the sensitivity. Proper beam detection is vital for safety and accessibility.
Safety Edge Configuration
Understanding Safety Edges: The Besam SL500 incorporates safety edges – pressure-sensitive sensors installed on the door’s leading edge – as a critical safety feature. These edges immediately halt and reverse the door’s movement upon contact with an obstruction‚ preventing injuries.
Configuration & Testing: Verify the safety edges are correctly wired to the control panel. During initial setup and routine maintenance‚ thoroughly test each safety edge by gently pressing along its entire length. The door should instantly stop and reverse direction.
Sensitivity Adjustment: Some models allow for sensitivity adjustment. Lower sensitivity requires greater pressure to activate‚ while higher sensitivity is more responsive. Ensure the setting provides reliable protection without being overly sensitive. Regularly inspect safety edges for damage or wear‚ replacing them as needed to maintain optimal safety.
Timer Settings & Customization
Adjusting Door Hold Times: The Besam SL500’s control panel allows customization of timer settings‚ primarily controlling the door’s open and close durations. Adjust the ‘open time’ to accommodate pedestrian traffic flow‚ ensuring sufficient time for entry and exit. Similarly‚ modify the ‘close time’ to balance convenience with safety.
Delay Timers: Utilize delay timers to prevent the door from immediately re-closing after someone passes through. This is particularly useful in high-traffic areas. Experiment with different settings to find the optimal balance for your specific needs.
Programming Considerations: Remember to document all timer adjustments for future reference. Incorrect settings can compromise safety or convenience. Refer to the advanced settings section for detailed programming instructions and troubleshooting tips.